MVB-Ex-S1
The valve block MVB-Ex-S1 (1.4305) with 2/2-way solenoid valves is made for stream switching. The solenoid valve block itself is available in 3 basic units with 2, 3 or 4 gas inlets each.
Discover our variety of Solenoid Valve Block Products.
• Off- and changeover switching of gas streams
• Application for pure, aggressive and corrosive gases
• Fast response time via low volume
• Variously configurable
• Easy to maintain
• Compact design
• Easily extendible
Click to open the brochure.
The valve block MVB-Ex-S1 (1.4305) with 2/2-way solenoid valves is made for stream switching. The solenoid valve block itself is available in 3 basic units with 2, 3 or 4 gas inlets each.
The valve block MVB-Ex-S2 (1.4305) with 3/2-way solenoid valves is made for stream switching to an analyzer. The second switching position is for pre purging, this means the lines and the valve block will be flushed with sample gas. If pre purging is not necessary, e.g. for calibration gases the relevant bypass will not be drilled.
The solenoid valve block 2-row made of 1.4305 is used for stream switching up to 10 different streams. The second valve row is for quick pre purging.
The solenoid valve block 2-row with purging is used for stream switching and for purging the analyzer in case of a power failure. This feature is recommended if an analyzer with a long start up time e.g. a moisture analyzer is used. The second valve row is for a quick pre purging.
The solenoid valve block 3-row is used for air monitoring, especially if a redundant measurement is needed. The basic unit of this valve block consists of a 2-row valve block with 8 sample gas inlet and the redundant stream selection valves and a bypass block with valves for pre purging.
The single solenoid valve block 3/2-way made of 1.4305 is used for the switching between two gas sources.
The solenoid valve block DBB-S2 is a multidimensional valve block made of 1.4305. It is designed for the US market and has a double block and bleed stream selection.
The solenoid valve block EAG made of 1.4305 acts as an on/off switch for gas conditioning elements. With this function a CO2 absorber could be switch in the sample gas way for a certain length of time.
The solenoid valve block EAG made of 1.4305 acts as an on/off switch for gas conditioning elements. With this function a CO2 absorber could be switch in the sample gas way for a certain length of time.
The standard solenoid valve block compact is a further development of the standard block. Due to its reduced length of the block can be equipped with up to 20 gas inlets.
The standard solenoid valve block of 1.4305 is used for stream switching up to 10 different streams.
The standard solenoid valve block with purging made of 1.4305 is used for stream switching and for purging the analyzer in case of a power failure.