Gas Industry

SAM-1000

SAM-1000

The sample handling module series SAM-1000 is used to connect different measuring points to analyzers. Because of its modular design, the sample handling module can be used for various applications in the chemical and petrochemical industries for gaseous high-purity gases.  

SAM-1000_DPS

SAM-1000_DPS

The sample handling module SAM-1000_DPS replaces the URSL systems. The URSL system is characterized by its flexible use in the range of loading and fillings systems. The flexibility is achieved in the SAM-1000_DPS by 3 different standard valve modules, the standardized electronic equipment and the new software. All specific project settings are stored in the sample handling module via touch panel.

SAM-1000_DP

SAM-1000_DP

The sample handling module SAM-1000_DP is used for sample switchover up to 8 different sample streams at cylinder and truck fillings plants. The module characterize itself of its individual configuration and is equipped with a quick purge feature. The pre purge function allows a very fast response of the analyzer system and reduce the measure and waiting time of the operators or truck drivers. The communication with the DCS based on Profibus DP. The module is controlled by a 3,8” touch panel.

SAM-1000_DP2

SAM-1000_DP2

The sample handling module SAM-1000_DP2 is used for sample switchover up to 8 different sample streams at cylinder and truck fillings plants. The module characterize itself of its individual configuration and is equipped with a pre purge feature. The pre purge function allows a very fast response of the analyzer system and reduce the measure and waiting time of the operators or truck drivers. The communication with the DCS based on Profibus DP. The module is controlled by a 5,7” touch panel.

SAM-1000_ONE

SAM-1000_ONE

The sample handling module SAM-1000_ONE is used for sample switchover up to 16 different sample streams at cylinder and truck fillings plants. The module characterize itself of its compact double block and bleed function and is equipped with a pre purge feature. The pre purge function allows a very fast response of the analyzer system and reduce the measure and waiting time of the operators or truck drivers. The communication with the DCS based on Profibus DP. The module is controlled by a 5,7” touch panel.

SAM-3000 / SAM-1950

SAM-3000 / SAM-1950

The sample handling module SAM-3000 is a 19" rack unit witch 4 RU. It can switch up to 4 measuring point could also test gases to the gas analyzer.

SAM-3500 / SAM-1950_DP

SAM-3500 / SAM-1950_DP

The sample handling module SAM-3500 is a further development of the SAM-3000. It is a Profibus compatible module wicht can read measured values from non-Profibus analyzers digitally or analogue and, in addition, is able to process signals from contact pressure gauges.

Power Distribution unit PDU

Power Distribution unit PDU

The power distribution unit is used for 19“ rack mount systems. It provides space for applicable equipment because of its compact design, for example in analysis systems for analyzers and accessories. Each current circuit has its own breaker.

MVB-Ex-S1

MVB-Ex-S1

The valve block MVB-Ex-S1 (1.4305) with 2/2-way solenoid valves is made for stream switching. The solenoid valve block itself is available in 3 basic units with 2, 3 or 4 gas inlets each.

MVB-Ex-S2

MVB-Ex-S2

The valve block MVB-Ex-S2 (1.4305) with 3/2-way solenoid valves is made for stream switching to an analyzer. The second switching position is for pre purging, this means the lines and the valve block will be flushed with sample gas. If pre purging is not necessary, e.g. for calibration gases the relevant bypass will not be drilled.

MVB-2SP

MVB-2SP

The solenoid valve block 2-row with purging is used for stream switching and for purging the analyzer in case of a power failure. This feature is recommended if an analyzer with a long start up time e.g. a moisture analyzer is used. The second valve row is for a quick pre purging.

MVB-3

MVB-3

The solenoid valve block 3-row is used for air monitoring, especially if a redundant measurement is needed. The basic unit of this valve block consists of a 2-row valve block with 8 sample gas inlet and the redundant stream selection valves and a bypass block with valves for pre purging.

MVB-DBB-S2

MVB-DBB-S2

The solenoid valve block DBB-S2 is a multidimensional valve block made of 1.4305. It is designed for the US market and has a double block and bleed stream selection.

MVB-EAG

MVB-EAG

The solenoid valve block EAG made of 1.4305 acts as an on/off switch for gas conditioning elements. With this function a CO2 absorber could be switch in the sample gas way for a certain length of time.

MVB-GC

MVB-GC

The solenoid valve block EAG made of 1.4305 acts as an on/off switch for gas conditioning elements. With this function a CO2 absorber could be switch in the sample gas way for a certain length of time.

MVB-K

MVB-K

The standard solenoid valve block compact is a further development of the standard block. Due to its reduced length of the block can be equipped with up to 20 gas inlets.

Purge Gas Unit PGU

Purge Gas Unit PGU

Inert gas is introduced to dilute or purge any escaping process gases during the air separation process in cold boxes or in tubes and apparatus cases. For this, CGS purge gas units are used, depending on the application, so as to keep the defined, inflowing inert gas at a constant using the appropriate counter pressure.

Pressure regulator in protection box - PCV

Pressure regulator in protection box - PCV

The pressure regulator in protection box is served to reduce gaseous medium. The device needs to be assembled directly at the sampling point by the wall mount kit. Also a heating as well as with solenoid valve to switch off in case of failure can be added.

Gas-Wash-Saturator Bottle

Gas-Wash-Saturator Bottle

The gas-wash-saturator bottle can be used for different applications. Filled with a liquid medium, the product is applicable as a gas-wash bottle or gas-saturator bottle.

Restrictor

Restrictor

Restrictors from CGS are suitable for flow rate or rather mass limitation of incoming gases. This device avoid cirtical gas concentration around work areas, for example by leckages or tube damages.

Temperature Controller UNI 2000

Temperature Controller UNI 2000

This device is made for temperature controlling of heaters, heated sample gas lines or heated systems. One heating loop can be controlled.  

Temperature Controller UNI 2010

Temperature Controller UNI 2010

This device is made for temperature controlling of heaters, heated sample gas lines or heated systems. One heating loop can be controlled. The controller is suitable for Top-hat rail mounting.